About this tool
Warm air holds more water vapour than cold air. When room air cools down at a cold outside wall, a window reveal or behind a wardrobe, the relative humidity right at the surface rises. At the dew point, water condenses; according to DIN 4108-2, mold grows as soon as a surface stays at 80 % relative humidity. The calculator shows both limits for your room air.
If you also enter the measured surface temperature, it rates the spot: no risk, mold risk or condensation. With the outdoor temperature it also calculates the surface’s temperature factor f_Rsi and the value it would need under these conditions. It uses the Magnus formula (Sonntag constants) right in your browser.
How it works
- Enter the room temperature and relative humidity, e.g. from a hygrometer.
- Read the dew point and mold limit: surfaces colder than the mold limit are at risk.
- Optional: measure the coldest spot of the wall with an infrared thermometer and enter it together with the outdoor temperature to see the risk and temperature factor.
Frequently asked questions
What is the dew point?
The temperature to which air has to cool for its water vapour to condense. At 20 °C and 50 % relative humidity it is about 9.3 °C – so a surface at 9 °C gets wet.
Why is the mold limit higher than the dew point?
Mold does not need liquid water. According to DIN 4108-2 it is enough for a surface to stay at 80 % relative humidity for a longer time. At 20 °C and 50 % room humidity that happens at a surface temperature of 12.6 °C.
What does the temperature factor f_Rsi mean?
f_Rsi = (θsi − θe) / (θi − θe) describes how warm an inside surface stays relative to the inside and outside temperature. DIN 4108-2 requires at least 0.70 at thermal bridges, designed for 20 °C inside, 50 % humidity and −5 °C outside. If your conditions need a higher value, lowering the humidity helps most.
What humidity is good for living spaces?
Typically 40 to 60 % at around 20 °C. The colder the outside walls, the lower the humidity should be in winter. How much water the air holds is shown by the absolute humidity in g/m³.
How accurate is the calculation?
Between −45 and 60 °C the Magnus formula deviates only by tenths of a degree from more exact methods. The measurement error is usually larger: cheap hygrometers are often 5 % off. To convert a temperature to Fahrenheit, use the Unit Converter.