PCB Trace Width Calculator

Minimum PCB trace width for a current – or the current a trace can carry – after IPC-2221, for outer and inner layers, with resistance and voltage drop.

Runs locally in your browser
A
mm
Copper
Minimum width
0.781 mm · 30.8 mil
Cross-section0.0274 mm²

IPC-2221 is a conservative rule of thumb from the 1950s, valid up to about 35 A, 10–100 K rise and 400 mil width. IPC-2152 gives more accurate values that also depend on the board and nearby planes.

About this tool

How wide must a trace be for 2 A? The calculator uses the IPC-2221 formula: I = k · ΔT^0.44 · A^0.725, with the cross-section A in mil² and k = 0.048 for outer layers or 0.024 for inner layers. From current, copper thickness and allowed temperature rise it gives the minimum width – or, the other way round, the maximum current for a width.

With a length it also shows the trace’s resistance, voltage drop and power loss, using the resistivity of copper at ambient temperature plus the rise. Copper thicknesses from 0.5 to 3 oz are available as presets.

How it works

  1. Choose “Current → width” or “Width → current” and enter the current or the width in mm.
  2. Set the copper thickness (usually 35 µm = 1 oz), the allowed temperature rise (often 10 K) and the layer.
  3. Optionally enter the trace length to see resistance, voltage drop and power loss.

Frequently asked questions

Why do inner layers need wider traces?

Inner layers shed heat less well because they are surrounded by base material. IPC-2221 therefore halves the factor k; for the same current and rise an inner layer needs about 2.6 times the cross-section.

What does 1 oz copper mean?

1 oz/ft² of copper is the amount that, rolled out over one square foot, is about 35 µm (1.37 mil) thick. Standard boards mostly use 35 µm; for high currents there is 70 µm (2 oz) and more.

Which temperature rise should I choose?

10 K is a common, cautious value. A higher rise allows narrower traces, but the trace must not reach the permitted temperature of the base material (around 130 °C for most FR4), and nearby parts heat up too.

How accurate is IPC-2221?

The formula is based on measurements from the 1950s and is usually conservative. The newer IPC-2152 takes board thickness, copper planes and mounting into account and often allows narrower traces. For wiring off the board there is the Cable Voltage Drop Calculator calculator.

How much power is lost in the trace?

With a length the calculator shows P = I² · R. Calculate voltage, current and resistance in general with the Ohm’s Law Calculator calculator.